specifications: [[item.skuinfo]]
price: [[item.currency]][[item.price]]
Price
This store has earned the following certifications.
Product Description The WJL-6000S is a high sensitivity corona HVAC leak detector with a visualized alarm display. Its adjustable sensitivity ensures automatic and optimal detection, resulting in more accurate leak location. It can detect all halogen refrigerants, including R134a, R410a, R12, R22, R600a, R404a, and R1234yf.
Concentration Indicator When a gas leak is detected, the beep frequency of the detector will increase. The more gas leaked, the faster the buzzer will beep. The first indicator will flash quickly and the other four LEDs will light up based on the concentration of the leaked gases. The first indicator also indicates both the leak and battery level. If it blinks in orange, it means the battery is low.
Corona Sensor The detector can respond to all halogenated gases, including CFCs (e.g., R12, R11, R500, R503), HCFCs (e.g., R22, R123, R124, R502), HFCs (e.g., R134a, R404a, R410a, R1234yf), and blends like AZ-50, HP62, and MP39.
7 Adjustable Sensitivity There are 7 levels of selectable sensitivity, with the maximum sensitivity being 0.21oz/yr. A smaller leak will require a higher sensitivity grade. The detector will beep more rapidly and the indicator will flash faster when there are more refrigerants present.
Audible and Visual Alerts The detector provides audible alerts through a buzzer alarm and visual alerts through LED light flashes. It also features dual battery indicators. A green indicator means the detector is suitable for the job, while an orange indicator means the batteries need to be replaced as soon as possible.
Flexible Probe The detector comes with a flexible probe that is approximately 7.87 inches long. This allows for detection in difficult and hard-to-reach areas. The sensor tip is also replaceable, ensuring more accurate detection.
4AAA Batteries The detector requires 4 AAA batteries for operation, with a battery life of approximately 50 hours. It comes with a portable black bag for easy carrying and storage. Please note that batteries are not included.
Technical Specifications - Sensor lifetime: 24 hours - Sensitivity range: 7 levels - Maximum sensitivity: 6g/yr - Response time: less than 3 seconds - Warm-up time: 6 seconds - Reset time: 2 seconds - Refrigerants: CFCs/HCFCs/HFCs/HCs/HFOs - Power supply: 4 AAA alkaline batteries (not included) - Approvals: Compliant to Standard: SAE-J1627, EN 14624 - Operating temperature: 0℃-52℃ (30℉ to 125℉) - Overall size: 92.62.6 in - Probe length: 7.9 in
ILD-100H: Add to Cart CPU-1G: Add to Cart IR-200: See Details HLD-200: Add to Cart LD-100+: See Details ILD-200: Add to Cart
Customer Reviews - WJL-6000S: 4.6 out of 5 stars, 733 reviews - ILD-100H: 4.3 out of 5 stars, 272 reviews - CPU-1G: 4.4 out of 5 stars, 134 reviews - IR-200: 4.3 out of 5 stars, 685 reviews - HLD-200: 4.1 out of 5 stars, 90 reviews - LD-100+: 4.6 out of 5 stars, 733 reviews
Price - WJL-6000S: $149.99 - ILD-100H: $55.00 - CPU-1G: $41.99 - IR-200: $201.99
Sensor Type - WJL-6000S: Heated Diode - ILD-100H: Corona - CPU-1G: Infrared & Heated Diode - IR-200: Corona - HLD-200: Heated Diode - LD-100+: Infrared
Battery Required - WJL-6000S: 4 AAA alkaline batteries - ILD-100H: 2 C batteries - CPU-1G: 2 AA batteries - IR-200: Li-1800mA/h - HLD-200: Li-3000mA/h - LD-100+: Li-3000mA/h
Sensor Life - WJL-6000S: ≥ 500 hours - ILD-100H: ≥ 24 hours - CPU-1G: ≥ 10 years/2 years - IR-200: ≥ 24 hours - HLD-200: ≥ 500 hours - LD-100+: ≥ 10 years
Probe Length - WJL-6000S: 14.37 inches - ILD-100H: 13.98 inches - CPU-1G: 14.37 inches - IR-200: 12.01 inches - HLD-200: 14.37 inches - LD-100+: 14.37 inches
Reset Function - WJL-6000S: Auto & Manual - ILD-100H: No - CPU-1G: Auto & Manual - IR-200: No - HLD-200: Auto & Manual - LD-100+: Auto
Q: Is it normal for the device to start beeping when turned on? A: Yes, it beeps upon powering on, and when a leak is detected, the alarm sound becomes more urgent.
Q: Why does the product alarm when not in a leaking environment? A: There could be several reasons: 1. Probe blockage, clean according to the manual. 2. Probe damaged, replace it. 3. Circuit board damage. Additionally, temperature greatly affects the sensor.
Q: Why does the product fail to power on? A: There could be several reasons: 1. This product does not include batteries, install them before use. 2. Poor contact in the battery compartment. 3. Knob switch damaged.
[All Halogenated Gas] The Freon leak detector can detect R22, R134A, R404A, R410A, R1234YF, and all halogenated refrigerants, including HFCs, CFCs, HCFCs, and blends.
[7 Adjustable Sensitivity] Turn the knob to select the desired sensitivity level. The maximum sensitivity is 0.21oz/yr, making it suitable for self-checking auto AC or air conditioning systems.
[Multiple Indicators] The detector features audible and visual indicators for gas leakage and dual battery indicators.
[Turn On and Use] The electronic refrigerant leak detector responds within 3 seconds. It has a warm-up time of 6 seconds, which is the shortest among gas detectors.
[7.9-inch Probe] The flexible probe allows for detection in difficult and hard-to-reach areas. We also offer 24/7 US Technician Support via Email and Phone.
product information:
Attribute | Value | ||||
---|---|---|---|---|---|
brand | Elitech | ||||
style | modern | ||||
power_source | Battery Powered | ||||
color | WJL-6000 | ||||
product_dimensions | 1.37"D x 1.37"W x 5.9"H | ||||
item_weight | 7.2 ounces | ||||
alarm | Audible, Visual | ||||
operating_humidity | 95 percent | ||||
upper_temperature_rating | 52 Degrees Celsius | ||||
sensor_type | Ionization | ||||
manufacturer | Elitech | ||||
upc | 705911761681 841161102970 841161102918 | ||||
item_model_number | WJL-6000 | ||||
batteries | 4 Lithium Metal batteries required. | ||||
is_discontinued_by_manufacturer | No | ||||
manufacturer_part_number | WJL-6000 | ||||
oem_part_number | WJL-6000 | ||||
voltage | 220 Volts | ||||
wattage | 1.5 watts | ||||
customer_reviews |
| ||||
best_sellers_rank | #25,428 in Automotive (See Top 100 in Automotive) #171 in Air Conditioning Line Repair Tools | ||||
date_first_available | September 16, 2015 |